Pfeiffer Vacuum’s five tips to improve your leak testing process

2022-05-14 00:51:30 By : Ms. Amy Yan

The conditions under which HVAC-R products are leak-tested depend on many considerations that Pfeiffer Vacuum designs for maximum efficiency and lowest costs over the complete product life cycle of HVAC-R systems.

Please enter a work/business email address

By clicking the Download Free Whitepaper button, you accept the terms and conditions and acknowledge that your data will be used as described in the Pfeiffer Vacuum privacy policy

By downloading this Whitepaper, you acknowledge that we may share your information with our white paper partners/sponsors who may contact you directly with information on their products and services. Visit our privacy policy for more information about our services, how we may use, process and share your personal data, including information on your rights in respect of your personal data and how you can unsubscribe from future marketing communications. Our services are intended for corporate subscribers and you warrant that the email address submitted is your corporate email address.

Manufacturers are under a legal obligation to reduce leaks from heating, ventilation, air conditioning and refrigeration (HAVC-R) equipment they produce.

Under the European Fluorinated Gas (F Gas) Regulations, which are based on the 2016 Kigali Amendment to the Montreal Protocol, manufacturers have to guard against and reduce leakages, and be able to document the steps they have taken to achieve this.

Some of the effects of not carrying out comprehensive leak tests during production to avoid refrigerant leakage can be:

This is critical prior to certifying a piece of equipment ready for use. It is generally accepted that prior to, and during, filling an HVAC-R system with refrigerant, all of its parts need to be free from moisture.

If any water remains on internal surfaces any component – compressor, condenser, evaporator, valves, and tubing. This water could freeze and either block a small pipe or a mechanical component like a valve etc. It can also react with the refrigerants forming acids to cause corrosion or solid deposits to foul systems.

All these issues can be eliminated by well-planned and executed vacuum drying procedures. It helps to extend the useful life of any HVAC-R system to which it has been applied. The moisture is removed using either low-speed, oil-sealed, rotary vane or scroll vacuum pumps providing a stable vacuum to avoid it freezing in the lines. The drying process is carried out under pressures in the mbar range.

Tip 2: Effect of tracer gas dilution

Tracer gases used to pressure test units under test for leakages after vacuum drying can be an expensive proposition unless the system is carefully designed to recover as much of the gas after use as possible.

Leak tests are carried out as a minimum at the operating pressure the unit will face during its working life. When the system is deemed free from moisture or air the tracer gas, either Helium or Hydrogen, is introduced under pressure to test for leaks, so it can reach every part of the HVAC-R refrigerant circulation system and has no interference with other molecules.

The gas concentration, usually much below 100%, will spread throughout the system as it is put under pressure. Using lower concentrations of Helium (which is becoming more and more expensive) and Hydrogen is one of the key methods for saving on costs.  A recovery system that can recoup gasses used for leak tests can be an important consideration, but only after a careful review of its ROI to ensure it will be a cost-effective investment.

Pfeiffer Vacuum has a broad range of products to set up leak detection systems in a wide variety of HVAC-R applications. The equipment it supplies can be used to leak-test for Helium, Hydrogen or Forming gas (mix of 95% Nitrogen and 5% Hydrogen), which is used to evacuate and fill the component under test with pressurised gas. Then a sector field mass spectrometer can be used to detect any hydrogen or helium leaking from it. Measuring the amount of tracer gas in a controlled environment over time provides the leak rate.

The appropriate test pressure depends on both the systems to be leak-tested and the tracer gas. The starting point is to know the pressure under which the unit will be operating. Leak tests can be performed in a series, again depending on the conditions set by the above considerations.

According to the European standard DIN EN 378, the minimum leak test pressure should be 0.25 times the operating pressure, rising to 1.43 times the operating pressure, up to as much as 3 times the operating pressure to ensure complete safety of the unit under operational conditions.

Pfeiffer Vacuum engineers usually evaluate the best leak test pressures once they have full knowledge of the equipment and conditions of operation. They have to be careful of difficulties that may arise because if too much pressure is introduced, they may inadvertently alter the internal geometry of the unit and the leak tightness may be different than it was before doing the leak test so the standard rule here is really whenever it’s possible applied operating pressure.

So, the general rule is to begin with understanding the operating conditions of the equipment before planning the leak tests. This also ensures the engineer will use the correct gas mix and the correct gas volume for the most cost-efficient leak-testing setup.

Tip 4: Optimisation of sniffing process

Pfeiffer Vacuum offers a wide range of customer-oriented leak detection training where the operator can be taught the best possible way to achieve this optimisation.

Factors to be taken into consideration are:

The position relative to the leak test site is key also. The engineers are trained to move the probe from the bottom to the top of the leak test site (the tracer gases usually rise, so you follow its natural path). They systematically ‘bracket’ the leak test site by testing to the right and left also.

Other factors to consider are where the leak test is carried out and the flow rate (suction) of the sniffer probe. These are flexible considerations and are altered to suit the client’s needs.

Tip 5: Consideration of cost of ownership

Where the total cost of ownership is a consideration for maintenance intervals, the robustness of the system, tracer gas consumption and energy consumption, many factors decide which leak test and detection system combinations are suitable for a client.

Pfeiffer Vacuum engineers perform a detailed analysis of each client’s requirements and recommend the most suitable and cost-effective setup. This includes which tracer gas will be used and the gas recovery system, the leak-testing processes, equipment types and number, and the ongoing costs of materials. Owing to the experience of the engineers and the pedigree of Pfeiffer Vacuum’s equipment and after-sales service, the client will benefit from a least-cost, highest-efficiency support solution.

Please visit Pfeiffer Vacuum’s Leak Testing Services page for more information

Please enter a work/business email address

By clicking the Download Free Whitepaper button, you accept the terms and conditions and acknowledge that your data will be used as described in the Pfeiffer Vacuum privacy policy

By downloading this Whitepaper, you acknowledge that we may share your information with our white paper partners/sponsors who may contact you directly with information on their products and services. Visit our privacy policy for more information about our services, how we may use, process and share your personal data, including information on your rights in respect of your personal data and how you can unsubscribe from future marketing communications. Our services are intended for corporate subscribers and you warrant that the email address submitted is your corporate email address.